This file includes instructions for the Napco 1000e

hmfile_hash_080c7cce

For complete instructions, click the above link for the pdf manual. Click Thumbnail for expanded keypad view.

ARMING/DISARMING:

Away ARMING

Check to see that the green 'Status' light is lit. Enter your Arm/Disarm Code. The red 'Armed/Alarm' light will come on, and the green light will go off.

Stay Arming

This feature must be enabled by the dealer

1.Press the [B] key twice. The keypad will beep and 'Bypass' will be displayed.

2.Enter your Code to arm the remaining zones.

DISARMING

Enter your Arm/Disarm Code to disarm anytime the system is armed.

DISARMING ERROR

If you enter the wrong code you must wait at least 3 seconds before trying again.

BYPASSING (Shunting):

With the system disarmed.

1.Press [B] key .

2.Enter the 1-digit Zone Number(s) of the zone(s) to be bypassed (1-8).

 

Helpful Tip

To view shunted zones, press and hold the 2 key until the sounder beeps and continue to hold it down until all shunted  zones have been displayed..

Reset Function

Press and hold the 9 key until the sounder beeps.

Resets any sounder condition, AC power loss condition, Day Zone indication, and Fault Find Mode. May be programmed to reset the Fire Zone. Will clear the numerical zone(s) displayed after an alarm condition.

DOOR CHIME:

Press and hold the 5 key for 2 seconds until the sounder beeps.

Repeating this procedure will turn off this feature

Alarm Memory

If the red Armed light is flashing an alarm has occurred. The display will scroll through all violated zones.

After the panel is disarmed the display will continue to indicate violated zones until the Reset (9) key is held down, or until the panel is armed once again.

ALARM HISTORY:

1.Press and hold the [B] key until the sounder beeps.

2.Continue to hold it down until all the information has been displayed.

The numerical display will indicate the zones violated. Alarm history will remain in alarm memory until automatically reset by a new alarm condition,

TROUBLE COnditions:

The following system troubles will display on the keypad, whether armed or disarmed, accompanied by flashing LEDs:

AC  Failure

Low Battery

Failure to Communicate

Auto-Download Failure

The indication may be temporarily reset by holding down the 9 key, in order to check zone status, and/or arm the system. If the trouble is not corrected it will return after about 3 minutes.

If there is a trouble on the fire circuit, the bottom red Fire/Trouble light will flash and the sounder will pulse. Disarm the system (if armed), hold down the 9 key to silence the sounder, and call for service.

PROGRAMMING ACCESS CODES

ADDING OR CHANGING CODES

1.Press and hold the 8 key until the sounder beeps. This will put the system into User Program Mode.

2.Enter your Program Code into the keypad. The keypad lights will flash and the sounder will pulse.

3.Press the B key.

4.Enter the User Number (1 through 5)

Note: Code 5 is the Service Code. This is a temporary code designed to be used by contractors, guests etc.

5.Enter a Code of up to 6 digits (digits 1-9, cannot use a 0 in a user code)

6.Press the B key twice to exit the Program Mode.

ERASING A CODE

To Erase a code, repeat steps 1-4, and 6 (skip step 5).