<< Click to Display Table of Contents >> P9600 |
***FOR MORE DETAILED INSTRUCTIONS REFER TO
INDIVIDUAL PANEL MANUALS***
NAPCO 9600
Click above link to view the PDF Manual
ARMING: To arm with an outstanding trouble press RESET then arm normally.
Away Arming: Enter Access Code and press the ON/OFF key.
Stay Arming: Press the INTERIOR key, then enter Access Code and press the ON/OFF key.
DISARMING: Enter Access Code and the ON/OFF key. To clear Memory press the RESET key.
FIRE: Enter the Access code and press the ON/OFF key to turn off a fire alarm.
Press the RESET key to silence a fire alarm or reset the keypad after a fire alarm or trouble.
BYPASSING: Enter the Access Code and the BYPASS key. The Zone Number and BYPASS keys can then be pressed to bypass individual zones.
DOOR CHIME: Enter the User Program Mode:
1. Enter your Access Code, then press MENU to enter the Function Mode.
2. Answer NO (AWAY) until “Activate Chime Y/N” is displayed, then press YES (STAY).
TROUBLE CODES:
E01-00 AC power failure.
E02-00 System low battery.
E03-00 Communication failure.
E04-NN RF transmitter supervisory Failure; NN = transmitter number.
E05-NN RF transmitter low battery condition; NN = transmitter number.
E06-NN Receiver response failure; NN = receiver number.
E07-00 Download failure.
E08-00 Telephone line failure
E09-00 System cold start.
E10-NN Keypad response failure; NN = keypad number.
E11-NN Keypad tamper condition; NN = keypad number.
E12-NN Expansion zone module response failure; NN = module number.
E13-NN Expansion zone module tamper condition; NN = module number.
E14-NN Relay board response failure; NN = relay board number.
E15-NN Rf transmitter tamper condition; NN = transmitter number.
E16-NN Receiver jammed; NN = receiver number.
E17-NN Receiver tamper condition; NN = receiver number.
E18-NN Key fob transmitter low battery; NN = key fob transmitter number.
E19-00 User Program memory error.
E20-00 Dealer Program memory error.
E21-00 System shutdown.
E22-NN Sensor activity failure; NN = zone number.
E23-00 Burglary bus failure.
E24-00 Service message.
E39-00 Receiver capacity error.
E40-00 RF Self Test Fail
E50-00 Alarm Output Supervisory
E51-00 Bell Supervisory
ACCESS CODES: It is highly reccomended that all requests for access code changes be referred to the Dealer.
Access Code:
1) Enter Access Code, followed by the FUNCTION key to enter the Function Mode.
2) Answer NO (INSTANT key) until "17" (Activate Program) is displayed, then press YES (INTERIOR key). NOTE: Press the BYPASS key to scroll backwards if needful.
3) The display will scroll the following: "P" (Program mode); 4 digits identifying software versions; then "UP" (User Program). The keypad will continue to flash while programming user codes.
4. Set the cursor to the user number with the the FUNCTION button.
5. Using the number buttons, enter a User Number as a two-digit number.
6) Set the cursor to the user code with the FUNCTION button and enter the new User Code using the number buttons. Press *0 for any blank locations until you end up back to the flashing "UP".
7. Press the ON/OFF to save the code in memory.
Repeat Steps 4 through 7 for each user.