PC 1864

<< Click to Display Table of Contents >>

Navigation:  »No topics above this level«

PC 1864

Return to chapter overview

This file includes instructions for the DSC PC1616/1832/1864

Keypad Diagram

Keypad Diagram

Keypad Display

Keypad Display

Older Style Keypad

Older Style Keypad

For complete instructions, click the above link for the pdf manual. Click Thumbnail for expanded keypad view.

ARMING/DISARMING:

ARMING IN STAY MODE

Press and Hold the Stay key for 2 seconds or enter the Access Code and do not leave the premises.

ARMING IN AWAY MODE

Press and Hold the Away key for 2 seconds or enter the Access Code or hit * 0

DISARMING

Enter your Access Code to disarm anytime the system is armed.

DISARMING ERROR

If your code is invalid, the system will not disarm and a 2 second error tone will sound. If this happens hit # key, and try again.

 

BYPASSING:

With the system disarmed.

1.Press * to enter the function menu. The keypad may display "Press * or < > Zone Bypass".

2.Press 1 then your Access Code (if required). The keypad may display "Scroll to < > Bypass Zones".

3.Enter the 2-digit Zone Number(s) of the zones to be bypassed (01-64).

When using the PK5500/RFK5500 keypads, you can also use the < > Scroll keys to find the zone to be bypassed, and then press * to bypass the zone. The keypad will display a "B" to indicate zone is bypassed

4.To unbypass a zone, enter the 2-digit Zone Number(s) of the zones to be unbypassed.

When using the PK5500/RFK5500 keypads, you can also use the < > Scroll keys to find the zone, and then press * to unbypass the selected zone. The "B" will disappear from the display.

5.To exit bypassing mode and return to the Ready state, press #.

 

Helpful Tip

Bypassed zones are automatically cancelled each time the system is disarmed and must be bypassed again, if required, before the next arming.

 

DOOR CHIME:

To turn door chime on or off press and hold the CHIME key for 2 seconds, or press * 4.

MEMORY LIGHT:

Lights to indicate that an alarm has occurred

1.Press * 3 to view which sensor(s) generated the alarm.

2.The sensor # will flash.

If using the PK500/RFK5500 keypads, use the < > Scroll keys to view the sensor(s) in alarm memory

3.Press # to exit

4.To clear the alarm memory, arm and disarm the system.

TROUBLE CODES:

Refer to manual for detailed description of trouble conditions

1.Press * 2 to enter trouble display.

2.The keypad will display a number from 1 to 8 to indicate the particular trouble.

If using the PK5500/RFK5500 keypads, you can use the < > Scroll keys to scroll  through a list of trouble conditions

3. Press # to exit trouble display. The 'Trouble' light will stay on until the trouble is resolved.

Time & Date Programming

1.Press * 6 plus your Master Access Code to enter User Functions.

2.Press 1 to select Time & Date.

When using the PK5500/RFK5500 keypads,use the < > Scroll keys to find the menu option then press * to select it.

3.Enter the time in 24-hr. format (HH:MM), followed by the date (MM:DD:YY).

4.Press # to exit programming.

PROGRAMMING ACCESS CODES

It is highly recommended that all requests for assistance with access codes be referred to the dealer!

ADDING OR CHANGING CODES

1.Press * 5 plus the (Master Access Code)

2.Enter the 2-digit user number to be programmed (i.e. 06 for user access code 6; enter 40 for the Master Access Code).

When using the PK5500/RFK5500 keypads, you can use the < > Scroll keys to find the specific code and then press the * key to select.

3.Enter the new 4-digit Access Code

4.Enter another 2-digit user number to program, or press # to exit.

Proceed With Caution

Take special care when changing the Master Code. Errors changing the Master Code will likely require a service call from a technician to correct.The Master Code can not be deleted.

ERASING A CODE

To Erase a code, select the code and enter * as the first digit. If * is entered, the system will immediately delete the code and the user will be returned to select another code.