SP Series / Magellan 5000 Series

<< Click to Display Table of Contents >>

Navigation:  »No topics above this level«

SP Series / Magellan 5000 Series

Return to chapter overview

This file includes instructions for the Paradox SP5000/SP6000/SP7000 series, and the Paradox Magellan 5000/5050 panels.

MG10LED

MG10LED

MG32LED

MG32LED

MG32LCD

MG32LCD

MG32I

MG32I

For complete instructions click the above link for the pdf manual. Click thumbnails for expanded keypad views.

arming/disarming

Normal arming

Press ARM key, then enter your Access Code.

If you have access to both partitions, Press the key corresponding to the desired partition (1 or 2). For both partitions, press the other key after the confirmation beep.

Stay arming

Press the STAY key, then enter your Access Code.

If you have access to both partitions, Press the key corresponding to the desired partition, (1 or 2). For both partitions, press the other key after the confirmation beep.

DISARMING

Press OFF key, then enter your Access Code.

If you have access to both partitions, Press the key corresponding to the desired partition (1 or 2). For both partitions, press the other key after the confirmation beep.

BYPASSING

1.Press the BYP key.

2.Enter Access Code. The BYP key will flash.

3.Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the 2-digit Zone Number (e.g. zone 3 = 03). Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.

4.Press the ENTER key to save and exit.

Helpful Tip

Bypassed zones are automatically cancelled each time the system is disarmed and must be bypassed again, if required, before the next arming.The Fire zone can not be bypassed.

CHIME

Each keypad must be Chimed seperately. Blue text indicates different keypads.

MG10LED Keypads

Press & hold the zone key (1 to 0(10)). Accept beep = Chime on, Fail beep = Chime off.

MG32LED Keypads

1.Press & hold the MUSICAL NOTE key. The Arm1, Arm2, Stay1, and Stay2 LEDs will flash.

2.Select the numbers corresponding to the zones you want to Chime by entering the 2-digit Zone Number. The corresponding LED will light up. The keypad will automatically save the information once the 2-digit zone number is entered.

3.Press the ENTER key to exit.

To remove the Chime feature from a zone, in step 2 enter the zone number again so the number extinguishes or press the SLEEP key to remove Chiming from all zones programmed to Chime. Any zones that are already Chimed will also illuminate. Zones that remain unlit are not Chimed.

MG32I Keypads

1.Press & hold the MUSICAL NOTE key. The word 'Chime' will appear on the screen.

2.Select the numbers corresponding to the zones you want to Chime by entering the 2-digit Zone Number. The corresponding zone number will light up. The keypad will automatically save the information once the 2-digit zone number is entered.

3.Press the ENTER key to exit.

To remove the Chime feature from a zone, in step 2 enter the zone number again so the number extinguishes or press the SLEEP key to remove Chiming from all zones programmed to Chime. Any zones that are already Chimed will also illuminate. Zones that remain unlit are not Chimed.

MG32LCD KEYPADS

1.Press and hold the MUSICAL NOTE key.

2.Press 1 to select which zone to chime or press 2 to configure chime period. The chime period allows you to specify the time frame in which the zone will chime.

ALARM MEMORY

If an alarm has occurred on a zone, the respective zone LED will flash, the MEM key will light up, and the zones will be stored in memory. These respective LEDs will continue to flash until disarming even if the zones are restored.

To exit this mode and switch to live display mode before disarming, press the CLEAR key.

When the system is disarmed, the zones’ LEDs will turn off, while the MEM key remains lit. Press the MEM key to illuminate the LEDs corresponding to the zones that were in alarm.

The alarm memory will be erased when the next alarm occurs and after a valid code is entered or upon full-arming the system.

For the MG32LCD keypad, the screen will display if there are zones in memory. Press MEM to view all zones in memory; scroll using the Up Arrow and Down Arrow keys. Press BYP to view events. The alarm memory will be erased when the next alarm occurs and after a valid code is entered.

TROUBLE

When a trouble condition occurs, the TBL key will illuminate

1.Press the TBL key. The TBL key will flash and number(s) corresponding to the trouble(s) will illuminate (except MG32LCD)

2.Read the corresponding explanation of the trouble from the Trouble List below.

3.Press the CLEAR key to exit.

 

1.Wireless Zone Low Battery: The battery voltage in one or more wireless zones is getting low.

2.Power Trouble: Five types of power trouble: [1] The control panel is experiencing low/no battery. [2] There is an AC failure on the control panel. [3] There is an auxiliary overload on the control panel. [4] A wireless keypad is experiencing AC failure. [5] A wireless keypad is experiencing battery failure.

3.Bell Trouble: There is a bell disconnect/overload on the control panel.

4.Communication Trouble: Your alarm system, if monitored, could not communicate with the monitoring station.

5.Tamper/Zone Wiring Failure: A wiring problem is occurring on one or more zones.

6.Module Tamper Trouble: A module’s anti-tamper switch has been triggered.

7.Fire Loop Trouble: Indicates a wiring trouble on a fire zone.

8.Timer Loss: Your alarm system’s clock must be reprogrammed. This is the only trouble that we recommend that you correct. See PROGRAMMING DATE/TIME BELOW

9.Wireless Zone Supervision Loss: One or more wireless zones are no longer communicating with the control panel.

10.  Module Supervision Loss: One or more modules are no longer communicating with the control panel.

11.  Keypad Fault (MG32I/MG32LED/MG32LRF only): One or more keypads are no longer communicating with the control panel.

12.  [SLEEP] Keypad Fault (MG10LEDV/H only): One or more keypads are no longer communicating with the control panel.

PROGRAMMING DATE/TIME

1.From trouble, display (see above) Press 8 for Timer Loss.

2.Enter the hour and minutes. If the hour is between 01 and 12, you will need to select 1 for 24Hr format, 2 for AM, or 3 for PM setting. If the hour is above 12, the system will automatically select the 24Hr format.

3.Enter the year (4 digits).

4.Enter the month (2 digits).

5.Enter the day (2 digits).

6.Press CLEAR key to exit.

programming access codes

It is highly recommended that all requests for assistance with access codes be referred to the dealer!

Quick Tip

In the following instructions, the 'CIRCLE' key refers to the button on the keypad that looks like this:

 

Paradox Keypad 'Circle' Button

adding/changing access codes

1.Press the CIRCLE key.

2.Enter a Master Access Code

3.(Skip this step if using MG32LCD) The CIRCLE key will flash. When a zone LED or zone key is lit (not flashing), the user is already programmed.

4.Select a user by entering a 2-digit User Number (e.g. 0+9 for user 9) or use the Scroll keys and then press ENTER key.

For the MG10LEDV/H, press the key corresponding to the user number (e.g. 9 for user 9).

5.Enter a new Access Code.

6.Confirm the code.

7.Press a button on the designated remote or press ENTER key to skip if there is no remote to program.

8. (This step not available for non-partitioned system) Press 1 and/or 2 to assign the user to a partition.

9.Press ENTER key, the menu will now jump to the next available user, if you choose to continue.

deleting access codes

1.Press the CIRCLE key.

2.Enter a Master Access Code

3.Select a user by entering a 2-digit User Number (e.g. 0+9 for user 9) or use the Scroll keys and then press ENTER key.

For the MG10LEDV/H, press the key corresponding to the user number (e.g. 9 for user 9).

4.Press and hold the SLEEP key until you hear the Confirmation Beep