<< Click to Display Table of Contents >> PC 3000 |
This file includes instructions for the DSC PC3000 |
For complete instructions, click the above link for the pdf manual. Click Thumbnail for expanded keypad view.
ARMING/DISARMING
Stay ARMING
Check to see that the 'Ready' light is lit. Enter a 4-digit Access Code. The 'Armed' light will come on. Do not leave through an exit door.
AWAY ARMING
Check to see that the 'Ready' light is lit. Enter a 4-digit Access Code. The 'Armed' light will come on. Leave through an exit door.
DISARMING
Enter your Access Code to disarm anytime the system is armed.
DISARMING ERROR
If your code is invalid, the system will not disarm and a 2 second error tone will sound. If this happens hit # key, and try again.
BYPASSING
With the system disarmed.
1.Press * 1.
2.Enter the 2-digit Zone Number(s) of the zones to be bypassed (01-16).
3.To exit bypassing mode and return to the Ready state, press #.
Entering 0 0 instead of a 2-digit zone number will remove all bypasses.
Bypassed zones are automatically canceled each time the system is disarmed and must be bypassed again, if required, before the next arming. |
RESETTING SMOKE DETECTORS
Some smoke detectors require entering a keypad command to reset them after an alarm.
Press * then hold down the 4 key for several seconds. If the smoke has
cleared, the smoke detector will reset and the fire zone light will go out when the 4
key is released. If the smoke has not cleared from the detector, open a window or
door and fan clean air into the detector and try resetting again
DOOR CHIME:
1.Enter * 6 then the Master Access Code. The 'Program' light will be flashing.
2.Press 6. The keypad will beep 3 times.
3.Press # to exit
Repeating this procedure will turn off this feature
MEMORY LIGHT
Lights to indicate that an alarm has occurred
1.Press * 3 to view which zones generated the alarm.
2.Press # to exit
The memory will be cleared when the panel is re-armed
TROUBLE CODES
Press * 2 to enter trouble display. The 'Zone' lights will indicate the type of trouble condition
1.Low Battery
2.AC Fail
3.Day Zone Trouble
4.Telephone Line Problem
5.Failed Attempt To Communicate
6.6. Bell/Siren Circuit Trouble
7.Fire Zone Trouble
8.Reset Clock
Press # to exit trouble display. The 'Trouble' light will stay on until the trouble is resolved.
Time & Date Programming
1.Press * 6 plus your Master Access Code to enter User Functions.
2.Press 1 to select Time & Date.
3.Enter the time in 24-hr. format (HH:MM).
4.Press # to exit programming.
PROGRAMMING ACCESS CODES
It is highly recommended that all requests for assistance with access codes be referred to the dealer!
ADDING OR CHANGING CODES
1.Press * 5 plus the (Master Access Code). The 'Program' light will flash and the 'Zone' lights will show which codes have already been programmed. Up to 16 codes can be programmed.
2. Enter the 2-digit user number to be programmed (01-16).
3.Enter the new 4-digit Access Code
4.Return to step 2 to program another code, or, Press # to exit.
Take special care when changing the Master Code (Code 1). Errors changing the Master Code will likely require a service call from a technician to correct.The Master Code must not be deleted. |
ERASING A CODE
To Erase a code, follow the same procedure, except, at step 3, enter * * * * instead of a 4 digit number.