Advent

<< Click to Display Table of Contents >>

Navigation:  Alarm Panels > GE >

Advent

Previous pageReturn to chapter overviewNext page

Show/Hide Hidden Text

This file includes instructions for the GE Advent panel.

hmfile_hash_7b24c15e


For complete instructions, click the above link for the pdf manual. Click Thumbnail for expanded keypad view.

ARMING/DISARMING

ARMING IN HOME (STAY) MODE

1.From the main menu, press 1 + 2 keys.

2.Enter your Access Code, if prompted.

3.Press the * key twice to exit.

ARMING IN AWAY MODE

1.From the main menu, press 1 + 3 keys.

2.Enter your Access Code, if prompted.

3.Press the * key twice to exit.

DISARMING

1.From the main menu, press 1 + 1 keys.

2.Enter your Access Code, if prompted.

3.Press the * key twice to exit.

Canceling an alarm

Enter your Access Code within 5 seconds (programmable) of the alarm start.

Doing this will prevent Police and/or Auxiliary/Medical type alarms from reporting to the monitoring station. Fire alarms will still report. Advise the monitoring station if the alarm is false.

BYPASSING

Automatic Bypassing

To bypass a door or window for this arming session only.

1.Press 1 key, then press a number from 1 to 5, indicating the desired arming level.

2.Enter your Access Code.

3.Press 1 key to accept the open sensor.

The sensor stays bypassed only until the system is disarmed.

Manual bypassing

To bypass a door or window indefinitely.

1.From the main menu, press 1 + 7 keys.

2.Enter your Access Code.

3.Enter the desired Zone Number to be bypassed and press # (Enter).

The sensor stays bypassed until you unbypass the sensor using the same method.

Manually Resetting smoke detectors

Manually resetting a smoke detector following a test or alarm resets tripped detectors. This procedure is rarely needed because smoke detectors are automatically reset when an alarm is acknowledged or canceled.

1.From the main menu, press 8 + 9 keys.

2.Enter your Access Code.

DOOR CHIME

To turn door chime on or off, press the 1 + 7 buttons (from the main menu).

Checking the system status

When you want to know the current status of the system including its arming state and any current problems.

1.Press 1 + 9 keys.

2.Press UNDO ( * ) to quit.

hmtoggle_plus1What the Status and Trouble Beeps Mean

PROGRAMMING Access CODES

It is highly recommended that all requests for assistance with access codes be referred to the dealer!

adding new  Access Codes

1.From the main menu, press 1 + 8 keys.

2.Enter your Primary Access Code.

3.Press 1 key.

4.Enter the New Access Code and press # key.

5.Enter New Access Code again, and press # key.

6.Press * key twice to exit.

Changing an Access Code

1.From the main menu, press 1 + 8 keys.

2.Enter your Primary Access Code.

3.Press 4 key.

4.Enter the Access Code to be changed and press # key.

5.Enter New Access Code, and press # key.

6.Enter the New Access Code again, and press # key.

7.Press * key twice to exit.

Deleting an Access Code

1.From the main menu, press 1 + 8 keys.

2.Enter your Primary Access Code.

3.Press 2 key.

4.Enter the Access Code to be deleted and press # key.

5.Press * key twice to exit.