<< Click to Display Table of Contents >> HS 2016/2032/2064/2128 (NEO) |
This file includes information for the DSC HS2016/2032/2064/2128 (NEO Panels) For systems that use a touchscreen keypad, click this Touchscreen link for instructions. |
For complete instructions, click the above link for the pdf manual. Click Thumbnails for expanded keypad views.
ARMING/DISARMING
ARMING IN STAY MODE
Press and Hold the Stay key for 2 seconds or enter the Access Code or present your prox tag, and do not leave the premises.
ARMING IN AWAY MODE
Ensure that the 'Ready' icon is lit on the display
Press and Hold the Away key for 2 seconds or present your prox card and, if required, enter the Access Code, or hit * 0
To Cancel the arming sequence enter the Access Code.
DISARMING
Enter your Access Code or present your prox tag to disarm anytime the system is armed.
For wireless keypads, If the keypad is in sleep mode, press any key to wake it up, then enter your Access Code or present your prox tag.
DISARMING ERROR
If your code/prox tag is invalid, the system will not disarm and a 2 second error tone will sound. If this happens hit # key, and try again.
BYPASSING
With the system disarmed
Bypass a single zone
1.Enter * 1 (followed by the Master Access Code, if required)
2.Enter the 3-digit zone number
3.Hit the # button to exit
4.Arm the system as normal
Bypass all open zones
1.Enter * 1 (followed by the Master Access Code, if required)
2.Enter 998
3.Hit the # button to exit
4.Arm the system as normal
Clear bypass
1.Enter * 1 (followed by the Master Access Code, if required)
2.Enter 000
3.Hit the # button to exit
Bypassed zones are automatically canceled each time the system is disarmed and must be bypassed again, if required, before the next arming. |
DOOR CHIME
To turn door chime on or off press and hold the CHIME key for 2 seconds, or press * 4.
MEMORY LIGHT
Lights to indicate that an alarm has occurred
1.Press * 3 to view which sensor(s) generated the alarm.
2.Use the < > Scroll keys to view the sensor(s) in alarm memory
3.Press # to exit
4.To clear the alarm memory, arm and disarm the system.
resetting smoke detectors
Feature must be enabled by dealer
Press * 72 on the keypad. If this does not reset the smoke detector, please look here for additional information regarding smoke detectors.
TROUBLE CODES
Refer to user instruction manual for detailed instructions regarding identifying troubles
Press * 2 and then use the < > Scroll keys to scroll through a list of trouble conditions. Press # to exit trouble display. The 'Trouble' light will stay on until the trouble is resolved.
Time & Date Programming
Press * 6 plus your Master Access Code plus 01 . Enter the time in 24-hr. format (HH:MM), followed by the date (MM:DD:YY). Press # to exit programming.
PROGRAMMING ACCESS CODES
It is highly recommended that all requests for assistance with access codes be referred to the dealer!
ADDING OR CHANGING CODES
1.Press * 5 plus the (Master Access Code)
2.Enter the 2-digit user number to be programmed (i.e. 06 for user access code 6; enter 40 for the Master Access Code). You can also use the < > Scroll keys to find the specific code and then press the * key to select.
3.Enter the new 4- or 6-digit Access Code (the panel will have been previously programmed by the dealer to accept either 4- or 6-digit codes)
4.Enter another 2-digit user number to program, or press # to exit.
Take special care when changing the Master Code. Errors changing the Master Code will likely require a service call from a technician to correct. |
ERASING A CODE
To Erase a code, select the code and enter * as the first digit. If * is entered, the system will immediately delete the code and the user will be returned to select another code.