Instructions for Napco Gemini panels are based on the keypad used.

This file includes instructions for the Napco RP1CAe2 , RP2ASe2 , RP3DGTL keypads.

RP1CAe2 / K1CA

RP1CAe2 / K1CA

RP2ASe2 / K2AS

RP2ASe2 / K2AS

RP3DGTL / K3DGTL

RP3DGTL / K3DGTL

For complete instructions, click the above links for the pdf manuals. Click Thumbnails for expanded keypad views.

 

Helpful Tip

The ON/OFF button on the RP series works the same as the ENTER button on the K series

The FUNCTION button on the RP series works the same as the MENU button on the K series

The INTERIOR button on the RP series works the same as the STAY button on the K series

The INSTANT button on the RP series works the same as the AWAY button on the K series

ARMING/DISARMING (Non-Partitioned)

Away ARMING

1.Check to see that the green 'Status' light is lit.

2.Enter the Arm/Disarm Code, and then press the ON/OFF key.

Note: If you enter an incorrect code the keypad will display 'Invalid Entry, Try Again' or 'Wrong Code' or will beep 4 times signifying an error. Re-enter a correct code immediately.

Stay Arming (Interior Zone Bypass)

This feature must be enabled by the dealer. Bypasses zones designated as Interior Zones.

1.Press the INTERIOR Button.

2.Enter your Arm/Disarm Code and press the ON/OFF button.

Note: Some control panels have provisions for two separate groups of interior zones, if so...

Press the INTERIOR button once, followed by the ON/OFF button to bypass group One.

Press the INTERIOR button twice, followed by the ON/OFF button to bypass group Two.

Press the INTERIOR button 3 times, followed by the ON/OFF button to bypass both groups One and Two.

DISARMING

Enter your Arm/Disarm Code , then press the ON/OFF button to disarm.

Note: If you enter an incorrect code the keypad will display 'Wrong Code', or will beep 4 times signifying an error. Re-enter a correct code immediately.

ARMING/DISARMING (Partitioned)

To Arm Any Area

Code must be valid in the area in question

1.Press the Numerical Key representing the area number.

2.Press the * button, then the ON/OFF button. In effect you will now be in that area.

3.Enter your Arm/Disarm Code, then press the ON/OFF button to arm that area

To Arm All Areas

Not available on P1632/816 panels. Code must be valid in all areas

1.Press the 9 button.

2.Press the * button.

3.Enter your Arm/Disarm Code, then press the ON/OFF button.

Note: If any zone is not secured, the keypad will display, 'CAN'T ARM SYSTEM/AREA # IN TROUBLE', or 'CAN'T ARM / AREA #' or 'P' where '#' identifies the area number. All problem zones must be secured or bypassed before the area can be armed. If a System Trouble is indicated, the system may not be armed using this method.

Disarming All Areas

1.Press the 0 button

2.Press the * button

3.Enter your Arm/Disarm Code, then press the ON/OFF button.

BYPASSING

With the system disarmed.

1.Press BYPASS button .

2.Enter the 2-digit Zone Number of the zone to be bypassed.

Reset Function

Pressing the RESET button resets various System Troubles, Displays, etc. Resets residential smoke detector.

Resetting Fire Alarms/Fire Troubles

1.Disarm the system, if armed.

2.Press the RESET button to silence the sounder.

3.Press the RESET button again to clear the alarm/trouble

Alarm Memory

When the system is first disarmed after an alarm event, the keypad will display 'ALARM' followed by the zones violated.

To reset the display, note the zones violated, then press the RESET button.

DOOR CHIME

Note: Displayed messages are two lines long. Press the * key to display the second line.

1.Enter an Arm/Disarm Code.

2.Press the FUNCTION button.

3.Press the INSTANT button until the message 'ACTIVATE.../CHIME' or 'TURN ON/CHIME' or '07' is displayed.

4.Press the INTERIOR button to select this option.

A 'C' will appear in the display as long as the Chime Mode is active

5.To return to normal keypad operation, press the RESET button.

Note: To deactivate the chime follow the same procedure.

TROUBLE CONDITIONS

Note: Displayed messages are two lines long. Press the * key to display the second line.

1.Enter an Arm/Disarm Code.

2.Press the FUNCTION button.

3.Press the INSTANT button until the message 'DISPLAY.../SYS TRB' or 'DispSys/Trbl' or '04' is displayed.

4.Press the INTERIOR button to select this option.

A 1 or 2 digit error code will be displayed. See the 'System Trouble Error Codes' section of the relevant manual for descriptions

5.Press the NEXT and PRIOR buttons to scroll system troubles.

6.To return to normal keypad operation, press the RESET button.

PROGRAMMING ACCESS CODES

In systems with multiple keypads, only keypad #1 may be used to program codes.

RP1CAe2 / RP2ASe2 KeypadS

Programming/Changing Codes

1.Enter your Arm/Disarm Code then press FUNCTION key to enter Function Mode.

2.Answer NO (Press the INSTANT button) until you see the message 'ACTIVATE PROGRAM Y/N', or 'TurnOn Prog Yes/No'

Note: If you accidentally scroll past this selection, you can press the BYPASS button scroll back

3.Press the INTERIOR button.

4.Enter the 2-Digit User Number you wish to program, then hit the FUNCTION key (hit once for the RP2ASe2 or twice for the RP1CAe2)

5.Enter the new User Code (up to 6 digits).

6.Press the ON/OFF key to save the new code.

Note: Duplicate codes are not allowed, therefore a duplicate code entered in the LCD window will disappear when ON/OFF is pressed.

7.Repeat steps 4 - 6 for each additional code to be programmed.

8.Press RESET to exit User Program Mode.

Erasing Codes

1.Enter your Arm/Disarm Code then press FUNCTION key to enter Function Mode.

2.Answer NO (Press the INSTANT button) until you see the message 'ACTIVATE PROGRAM Y/N'.

Note: If you accidentally scroll past this selection, you can press the BYPASS button scroll back

3.Press the INTERIOR button.

4.Enter the 2-Digit User Number you wish to program, then hit the FUNCTION key (hit once for the RP2ASe2 or twice for the RP1CAe2)

5.Press *0 for each digit of the code to be erased (e.g. to erase a 4 digit code, enter *0 *0 *0 *0)

6.Press the ON/OFF key to save changes.

7.Repeat steps 4 - 6 above for each additional codes to be erased.

8.Press RESET to exit User Program Mode.

RP3DGTL Keypad

Programming/Changing Codes

1.Enter your Arm/Disarm Code then press FUNCTION key to enter Function Mode.

2.Answer NO (Press the INSTANT button) until you '17' is displayed.

Note: If you accidentally scroll past this selection, you can press the BYPASS button scroll back

3.Press the INTERIOR button.

The display will scroll the following: 'P' (Program mode); 4 digits identifying software versions; then 'UP' (User Program). The keypad will continue to flash while programming user codes.

4.Set the cursor to the user number with the FUNCTION button

5.Enter the 2-Digit User Number you wish to program

6.Continuing, set the cursor to the user code with the FUNCTION button, and enter the new User Code with the number buttons. Press *0 for any blank locations until you end up back to the flashing 'UP'

7.Press the ON/OFF key to save the new code.

8.Repeat steps 4 - 7 for each additional code to be programmed.

9.Press RESET to exit User Program Mode.

Erasing Codes

1.Enter your Arm/Disarm Code then press FUNCTION key to enter Function Mode.

2.Answer NO (Press the INSTANT button) until you see the message '17'.

Note: If you accidentally scroll past this selection, you can press the BYPASS button scroll back.

3.Press the INTERIOR button.

4.Enter the 2-Digit User Number you wish to erase.

5.Press the ON/OFF key to erase the code.

6.Repeat steps 4 and 5 above for each additional code to be erased.

7.Press RESET to exit User Program Mode.